Journal of Ultrasound in Medicine · 2013 · 16 citations · 22 references
MedicineCardiologyRadiologyDiagnostic ImagingDiagnostic RadiologyUltrasonographyAtrial FibrillationCardiac ImagingCardiovascular ImagingComputer-aided DiagnosisMedical ImagingTransesophageal EchocardiographyAccuracyAtrial Fibrillation ImagingDiagnostic Algorithm EvaluationGray-level Co-occurrence MatricesImaging Diagnosis Of ThrombosisIntracardiac Thrombus DetectionLeft Atrial Appendage ImagingLeft Atrial Appendage Thrombus
OBJECTIVES: We investigated whether transesophageal echocardiography (TEE) assisted with a computer-aided diagnostic (CAD) algorithm was superior to TEE in diagnosing left atrial (LA)/left atrial appendage (LAA) thrombi in patients with atrial fibrillation (AF) in a single prospective study. METHODS: Transesophageal echocardiography was performed in patients with AF, and images were reconstructed. Gray level co-occurrence matrix-based features were calculated and then classified using an artificial neural network. The original data and processed images by the CAD system were studied by 5 radiologists independently in a blind manner. The diagnostic performance of each radiologist was evaluated. RESULTS: One hundred thirty patients with AF were investigated. Thirty-one patients (23.9%) had a diagnosis of LA/LAA thrombi. The mean sensitivity ± SD of TEE for LA/LAA thrombi was 0.933 ± 0.027, which was noticeably improved by CAD (0.955 ± 0.021; P < .05). The specificity of TEE was 0.811 ± 0.055, which was markedly lower than that by TEE plus CAD (0.970 ± 0.009; P < .05). The positive predictive value of TEE was low (0.613 ± 0.073) compared to that of TEE plus CAD (0.908 ± 0.027; P < .001), whereas the negative predictive values were comparable for TEE, CAD, and TEE plus CAD. Diagnosis of an LA/LAA thrombus by TEE plus CAD had a higher accuracy rate (0.966 ± 0.011) than that by TEE (0.840 ± 0.047; P < .01). The mean area under the receiver operating characteristic curve (Az) for TEE was 0.834 ± 0.009 (95% confidence interval [CI], 0.815-0.852), which was markedly lower than the Az for TEE plus CAD (0.932 ± 0.005; 95% CI, 0.921-0.943). The use of CAD significantly improved the Az values for all 5 radiologists (P < .001). CONCLUSIONS: The CAD algorithm significantly improves the diagnostic accuracy of TEE for LA/LAA thrombi in patients with AF.
22
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation
Valentı́n Fuster, Lars Rydén, David S. Cannom et al. · Circulation · 2006 · 2.8K citations · Full text
Yoko Miyasaka, Marion E. Barnes, Bernard J. Gersh et al. · Circulation · 2006 · 2.6K citations · Full text
Automated breast cancer detection and classification using ultrasound images: A survey
Heng-Da Cheng, Juan Shan, Wen Ju et al. · Pattern Recognition · 2009 · 730 citations
Jack S. Shanewise, Albert T. Cheung, Solomon Aronson et al. · Journal of the American Society of Echocardiography · 1999 · 728 citations