Applied Optics · 1971 · 194 citations · 4 references
Natural SciencesPhysicsOpticsOptoelectronicsVisual OpticsFourier OpticsHolographyInterferometryOptical AberrationsOptical InstrumentationPhysical OpticsAtmospheric Turbulence CompensationHolographic InterferometryInterferogram AnalysisInterferometric MeasurementOptical Interferometry
It is shown that both single exposure and double exposure two-wavelength holography provide a good method of using visible light to obtain an interferogram identical to what would be obtained if a longer nonvisible wavelength were used. Both techniques provide for the real-time adjustment of defocus and tilt in the final interferogram. When both hologram exposures are made simultaneously, the sensitivity to air turbulence is essentially the same as if the longer nonvisible wavelength were used. Results are shown for testing both lenses and mirrors at equivalent wavelengths at 6.45 micro, 9.47 micro, 14.20 micro, 20.22 micro, and 28.50 micro obtained by using an argon laser for the visible light source.
4
Multiple-Index Holographic Contouring
J. S. Zelenka, Jerry R. Varner · Applied Optics · 1969 · 47 citations
Natural Sciences, Biomedical Engineering, Biomedical Imaging +10
Rough Surface Interferometry Using a CO_2 Laser Source
Charles R. Munnerlyn, M. R. Latta · Applied Optics · 1968 · 32 citations