2010 · 27 citations · 20 references
EngineeringElectrical EngineeringDynamical SystemsEnergy SystemsSystem DynamicsControl TheoryFrequency ResponsePower QualityPower SystemsTime-domain ResponseVoltage RegulationHarmonic ReductionHarmonic ResponseHarmonic Response AnalysisPower Flow ControlPower Quality IndicesReactive Power CompensationState-space EquationsSteady-state Response
The extended harmonic domain (EHD) method is used to obtain the harmonics in the dynamic and steady state response to disturbances for four common FACTS devices. The versatility of this method is demonstrated by applying it to a thyristor-controlled series compensator (TCSC), static reactive power compensator (SVC), static synchronous series compensator (SSSC), and unified power flow controller (UPFC). The derivation of the state-space equations that describe the dynamics of the above devices and their transformation into linear, time-invariant (LTI) systems using EHD is presented. The LTI systems are simulated in the presence of disturbances using MATLAB <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">®</sup> , and graphical depictions are used to illustrate the evolution in time of the harmonic coefficients and power quality indices such as RMS voltage and current, apparent power, active power, reactive power, and distortion power. This study shows the usefulness of this methodology in highlighting the sensitivity of the harmonic response of these devices to disturbances.
20
Generalized averaging method for power conversion circuits
S.R. Sanders, J.M. Noworolski, X.Z. Liu et al. · IEEE Transactions on Power Electronics · 1991 · 1.2K citations