Anesthesia & Analgesia · 2004 · 23 citations · 21 references
EngineeringBiostatisticsBiomedical Signal ProcessingHealth Data StandardsHealth Technology AssessmentPatient MonitoringPoint-of-care Diagnostic DevicesRespiratory Monitoring InstrumentsSignal EvaluationVital SignsVital Signs RecordingArterial Oxygen SaturationAssessment Of Oxygen SaturationData AvailabilityOxygen Saturation MeasurementOxygen Saturation MonitoringPulse OximetersPulse OximetrySignal Integrity Effects
UNLABELLED: Pulse oximetry manufacturers have introduced technologies that claim improved detection of hypoxemic events. Because improvements in signal processing and data rejection algorithms may differentially affect data reporting, we compared the data reporting and signal heuristic performance and agreement among the Nellcor N-395, Masimo SET, and GE Solar 8000 oximeters under a spectrum of conditions of signal integrity and arterial oxygen saturations. A blinded side-by-side comparison of technologies was performed in 27 patients, and data were analyzed for time of data availability, measures of agreement and signal heuristics, and warnings stratified by signal integrity and SpO(2). The Solar 8000 had less total data dropout than either of the new technologies. Masimo's LoSIQ (signal quality) heuristic rejected less data than Nellcor's MOT/PS (motion/pulse search) flag. When no signal heuristic was displayed, there was little difference in precision and bias between the two newer technologies; however, agreement between devices deteriorated in the presence of SIQ, MOT, or hypoxemia. Both newer devices flagged questionable data, but their use of different rejection algorithms resulted in different probabilities of presenting data. Therefore, with poor SIQ or during hypoxemia, the Nellcor N-395 and Masimo oximeters are not clinically equivalent to each other or to the older Solar 8000 oximeter. IMPLICATIONS: We compared new pulse oximeters from Nellcor and Masimo and found that, with good signal conditions, both new devices performed similarly to older technology. Overall, Masimo reported less data as questionable than Nellcor. With poor signal conditions or during hypoxemia, the new devices are not clinically equivalent to each other or to the older technology.
21
Randomized Evaluation of Pulse Oximetry in 20,802 Patients; II
N. W. Johannessen, Kurt Espersen, O Ravlo et al. · Anesthesiology · 1993 · 443 citations · Full text
Medicine, Anesthesiology, Surgery +17
Stephen Lawless · Critical Care Medicine · 1994 · 412 citations
Masimo Signal Extraction Pulse Oximetry
Julian M. Goldman, Michael T. Petterson, Robert J. Kopotic et al. · Journal of Clinical Monitoring and Computing · 2000 · 265 citations
Randomized Evaluation of Pulse Oximetry in 20,802 Patients; I
Tom Pedersen, Lars S. Rasmussen, Per Jensen et al. · Anesthesiology · 1993 · 233 citations · Full text