Physical Review A · 1997 · 30 citations · 13 references
Natural SciencesChemistryNuclear InstrumentationSpectroscopic AnalysisSpectroscopyAtomic SpectroscopyElectronic SpectroscopyMass SpectrometryCharge State DistributionsCharge-state DistributionElectric Dipole TransitionsElectron Beam Ion Trap ExperimentsIon Trapping TechniquesMultichannel Data AcquisitionNuclear Magnetic Dipole TransitionsState Identification
Kr spectra from 300 nm to 460 nm produced in an electron-beam ion trap (EBIT) are reported in this work. The spectra include magnetic dipole (M1) transitions from Kr XXIII and Kr XXII, as well as electric dipole (E1) lines of Kr II and Kr III. Two new capabilities of the EBIT at the National Institute of Standards and Technology, time resolved data acquisition and extracted ion analysis, are used to aid in the charge state identification.
13
Victor Kaufman, Jack Sugar · Journal of Physical and Chemical Reference Data · 1986 · 268 citations
R. E. Marrs, P. Beiersdörfer, Dieter Schneider · Physics Today · 1994 · 104 citations