MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAttenuation CorrectionBrain ImagingImage ReconstructionMagnetic Resonance ImagingMedical ImagingPositron Emission TomographyBayesian DeconvolutionDeconvolutionFunctional ImagingPartial Volume CorrectionPartial Volume Effect CorrectionPet Image ReconstructionRadiopharmaceutical UptakeVoxel-based Modeling
PURPOSE: Partial volume effect in positron emission tomography (PET) can cause incorrect quantification of radiopharmaceutical uptake in functional imaging. A PET partial volume correction method is presented to attenuate partial volume blurring and to yield voxel-based corrected PET images. METHODS: By modeling partial volume effect as a convolution of point spread function of the PET scanner, the reconstructed PET images are corrected by iterative deconvolution with an edge-preserving smoothness constraint. The constraint is constructed to restore discontinuities extracted from coregistered MR images but maintains the smoothness in radioactivity distribution. The correction is implemented in a Bayesian deconvolution framework and is solved by a conjugate gradient method. The performance of the method was compared with the geometric transfer matrix (GTM) method on a simulated dataset. The method was evaluated on synthesized brain FDG-PET data and phantom MRI-PET experiments. RESULTS: The true PET activity of objects with a size of greater than the full-width at half maximum of the point spread function has been effectively restored in the simulated data. The partial volume correction method is quantitatively comparable to the GTM method. For synthesized FDG-PET with true activity 0 μci/cc for cerebrospinal fluid (CSF), 228 μci/cc for white matter (WM), and 621 μci/cc for gray matter (GM), the method has improved the radioactivity quantification from 186 ± 16 μci/cc to 30 ± 7 μci/cc in CSF, 317 ± 15 μci/cc to 236 ± 10 μci/cc for WM, 438 ± 4 μci/cc to 592 ± 5 μci/cc for GM. Both visual and quantitative assessments show improvement of partial volume correction in the synthesized and phantom experiments. CONCLUSIONS: The partial volume correction method improves the quantification of PET images. The method is comparable to the GTM method but does not need MR image segmentation or prior tracer distribution information. The voxel-based method can be particularly useful for combined PET/MRI studies.
42
Correction for partial volume effects in PET: principle and validation.
Olivier Rousset, Yilong Ma, Alan C. Evans · PubMed · 1998 · 934 citations
Multi-modality image registration by maximization of mutual information
Frederik Maes, André Collignon, Dirk Vandermeulen et al. · 1996 · 804 citations
Hans W. Müller‐Gärtner, Jonathan M. Links, Jerry L. Prince et al. · Journal of Cerebral Blood Flow & Metabolism · 1992 · 758 citations
Medicine, Neuroscience, Radiology +17