Investigative Radiology · 1978 · 447 citations · 0 references
MedicineComputer ScienceRadiologyDiagnostic ImagingDiagnostic RadiologyEye MovementsComputer-aided DiagnosisEye Movement AnalysisMedical Image AnalysisMedical ImagingPulmonary ImagingVisual SearchComputer-aided DetectionDecision Making In SearchFalse Negative DetectionLung InspectionPulmonary Nodule DiagnosisRecognition ErrorsSearch Error RatesVisual Inspection
Eye movements were recorded while four subjects searched a set of 60 films, 24 normal and 36 abnormal for pulmonary nodules. Error rates, scanning patterns and the dwell time of fixation clusters on normal and nodule-containing areas of the film were studied. Using the assumption that prolonged dwell time indicates intensive processing of visual data, a model was developed for nodule detection that includes four steps: orientation, scanning, pattern recognition and decision-making. False-negative errors were divided into three classes: scanning errors, recognition errors and decision-making errors. Of 20 false-negative errors, 30% were considered scanning, 25% recognition and 45% decision-making.