Physics in Medicine and Biology · 2013 · 36 citations · 16 references
Veterinary MedicineBiomedical EngineeringRadiologyDiagnostic ImagingDiagnostic RadiologyOptimizationComputed TomographyDiagnostic Imaging SystemsImage OptimizationImage ReconstructionImage-guided TherapyMedical Imaging4D ReconstructionComputed Tomography AcquisitionCone-beam Computed Tomography ReconstructionInteger Quadratic ProgrammingMixed-integer ProgrammingMixed-integer Quadratic ProgrammingOptimization Of Scan ParametersTomography
Four dimensional cone beam computed tomography (4DCBCT) is an emerging clinical image guidance strategy for tumour sites affected by respiratory motion. In current generation 4DCBCT techniques, both the gantry rotation speed and imaging frequency are constant and independent of the patient's breathing which can lead to projection clustering. We present a mixed integer quadratic programming (MIQP) model for respiratory motion guided-4DCBCT (RMG-4DCBCT) which regulates the gantry velocity and projection time interval, in response to the patient's respiratory signal, so that a full set of evenly spaced projections can be taken in a number of phase, or displacement, bins during the respiratory cycle. In each respiratory bin, an image can be reconstructed from the projections to give a 4D view of the patient's anatomy so that the motion of the lungs, and tumour, can be observed during the breathing cycle. A solution to the full MIQP model in a practical amount of time, 10 s, is not possible with the leading commercial MIQP solvers, so a heuristic method is presented. Using parameter settings typically used on current generation 4DCBCT systems (4 min image acquisition, 1200 projections, 10 respiratory bins) and a sinusoidal breathing trace with a 4 s period, we show that the root mean square (RMS) of the angular separation between projections with displacement binning is 2.7° using existing constant gantry speed systems and 0.6° using RMG-4DCBCT. For phase based binning the RMS is 2.7° using constant gantry speed systems and 2.5° using RMG-4DCBCT. The optimization algorithm presented is a critical step on the path to developing a system for RMG-4DCBCT.
16
L.A. Feldkamp, L. C. Davis, J. W. Kress · Journal of the Optical Society of America A · 1984 · 6.2K citations
The role of radiotherapy in cancer treatment
Geoff P. Delaney, Susannah Jacob, C. Featherstone et al. · Cancer · 2005 · 1.7K citations · Full text
Respiratory correlated cone beam CT
Jan‐Jakob Sonke, Lambert Zijp, P. Remeijer et al. · Medical Physics · 2005 · 663 citations
Mitchell Machtay, Kyounghwa Bae, Benjamin Movsas et al. · International Journal of Radiation Oncology*Biology*Physics · 2010 · 301 citations