Measurements of electron density and temperature in the H-1 heliac plasma by helium line intensity ratios

Shuiliang Ma, J. Howard, B. D. Blackwell, Nandika Thapar

Review of Scientific Instruments · 2012 · 26 citations · 22 references

Concepts

Abstract

Electron density and temperature distributions in the H-1 heliac plasma are measured using the helium line intensity ratio technique based on a collisional-radiative model. An inversion approach with minimum Fisher regularization is developed to reconstruct the ratios of the local emission radiances from detected line-integrated intensities. The electron density and temperature inferred from the He I 667.8/728.1 and He I 728.1/706.5 nm line ratios are in good agreement with those from other diagnostic techniques in the inner region of the plasma. The electron density and temperature values appear to be a little high in the outer region of the plasma. Some possible causes of the discrepancy in the outer region are discussed.

References

22