Limits of temperature separation in a vortex tube

B. Ahlborn, Jonas Keller, R. Staudt, Gerhard Treitz, Eckhard Rebhan

Journal of Physics D Applied Physics · 1994 · 74 citations · 7 references

Concepts

Abstract

The heating and cooling in a vortex tube is attributed to conversion of kinetic energy into heat and to the reverse process. A two-component model yields the upper limit for the temperature increase on the hot side: (Th-To)/T0<or=X( gamma -1)/ gamma , and a lower limit for the temperature reduction on the cold side: Tc>or=T0(1-X)( gamma -1/ gamma ), where gamma =1.4 for air, and X=(p0-pc)/p0 is the normalized pressure drop between the inlet (p0) and the cold exhaust port (Pc) Extensive experimental data for a vortex tube of 18 mm inner diameter with working fluid air all fall between these limits. The model predicts that the inlet velocity reaches the speed of sound for X=0.7. No values X>0.7 could be obtained in these experiments, indicating that the flow always remain subsonic.

References

7