Otolaryngology · 2008 · 171 citations · 15 references
MedicineOtolaryngologySurgeryCochlear ImplantsOtologyVestibular AssessmentCochlear ImplantationOtologic SurgeryVestibular Evoked Myogenic PotentialsVestibular FunctionVestibular PhysiologyVestibular TestingCochleostomy ApproachCochleostomy InsertionFunctional DizzinessPostoperative DizzinessSaccular DysfunctionSaccular FunctionVestibular Function MonitoringVestibular Receptor Physiology
The study aims to determine how different cochleostomy techniques affect vestibular function and postoperative vertigo in cochlear implant patients. The authors retrospectively compared 62 patients undergoing anterior or round window cochlear implantation, evaluating vestibular function pre‑ and post‑operatively with DHI, caloric irrigation, VEMP, and ENG. Patients receiving the round window approach had significantly better postoperative VEMP (13% abnormal vs 50% for anterior), ENG (9.4% vs 42.9%), and lower vertigo rates (12.5% vs 23%), indicating the round window insertion reduces vestibular dysfunction and vertigo risk.
Objective To investigate the impact of different cochleostomy techniques on vestibular receptor integrity and vertigo after cochlear implantation. Study Design Retrospective cohort study. Subjects A total of 62 patients (17 to 84 years of age) underwent implantation via an anterior or round window insertion approach. Methods Two groups of cochlear implant patients were compared with respect to their pre‐ and postoperative vestibular function and the occurrence of postoperative vertigo. The data were related to the different cochleostomy techniques. The patients were tested by a questionnaire (dizziness handicap inventory, DIH), caloric irrigation (vestibulo‐ocular reflex, VOR) for the function of the lateral SCC and by vestibular evoked myogenic potential (VEMP) recordings for saccular function. RESULTS: Significant differences of postoperative VEMP responses (50% vs 13%) and electromystagmography (ENG) results (42.9% vs 9.4%) were found with respect to the 2 different insertion techniques. The number of patients with vertigo after the surgery as evidenced by DHI (23% vs 12.5%) was significantly different. Conclusion The used round window approach for electrode insertion should be preferred to decrease the risk of loss of vestibular function and the occurrence of vertigo.
15
Vestibular Effects of Cochlear Implantation
Craig A. Buchman, Jennifer J. Joy, Annelle V. Hodges et al. · The Laryngoscope · 2004 · 275 citations
Medicine, Audiology, Otolaryngology +17
Histopathologic Changes in the Vestibule after Cochlear Implantation
Hui‐Chi Tien, Fred H. Linthicum · Otolaryngology · 2002 · 160 citations