Droplet emission in liquid metal ion sources

T. Venkatesan, P. M. Petroff, D. Barr

Journal of Vacuum Science and Technology · 1981 · 50 citations · 0 references

Concepts

Abstract

Liquid indium ions sources were operated in a transmission electron microscope. The formation of a Taylor cone was directly observed during source operation. In addition, dynamic instabilities were observed on the needle shank behind the Taylor cone with the formation of liquid droplets which grew in size and left the shank. Droplets on the shank were also found in SEM observations of rapidly frozen liquid gold ion sources. The surface of silicon targets on which the ion current from a gallium ion source was allowed to impinge was studied by Rutherford backscattering spectrometry. The amount of material emitted from the ion source was measured as a function of the angle of emission and the ion current. A comparison of these emitted mass distributions with the corresponding current distributions indicated that the average mass to charge ratio of the beam decreased with angle of emission. In addition, the ratio of the amount of material to the total charge leaving the source was found to increase monotonically with the ion current with a sharp increase occurring for ion currents greater than approximately 10 μA.