Clinical Chemistry and Laboratory Medicine (CCLM) · 2002 · 51 citations · 21 references
PharmacyPharmaceutical AnalysisPharmaceuticsBiopharmaceuticsChromatographic AnalysisMass Spectrometric AnalysisAnalytical ChromatographyBioanalytical Method ValidationChromatographyClinical AnalysisImmunosuppressant MonitoringLiquid ChromatographyAnalytical Liquid ChromatographyElectrospray IonizationLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisLiquid Chromatography-mass Spectrometry Method DevelopmentMass Spectrometry Method ValidationOff-line Solid-phase ExtractionOn-line Solid-phase Extraction
Quantification of the new immunosuppressant sirolimus (syn. rapamycin; Rapamune) in whole blood by chromatography is essential for its clinical use since no immunoassay is available although monitoring is mandatory. Here we report on a rapid and convenient liquid chromatography (LC-tandem mass spectrometry method and describe our practical experience with its routine use. Whole blood samples were hemolyzed and deproteinized using an equal volume (150 microl) of a mixture of methanol/zinc sulfate solution containing the internal standard desmethoxy-rapamycin. After centrifugation, the clear supernatants were submitted to an on-line solid-phase extraction procedure using the polymeric Waters Oasis HLB material, with elution of the extracts onto the analytical column in the back-flush mode by column switching. For analytical chromatography a RP-C18 column was used with 90/10 methanol/2 mM ammonium acetate as the mobile phase. A 1:10 split was used for the transfer to the mass spectrometer, a Micromass Quattro LC-tandem mass spectrometry system equipped with a Z-spray source and used in the positive electrospray ionization mode. The following transitions were recorded: sirolimus, 931>864 m/z, and desmethoxy-rapamycin (I.S.), 901>834 m/z. The analytical running time was 5 min, including on-line extraction. The method has a linear calibration curve (r>0.99; range 1.6-50 microg/l) and is rugged and precise with monthly CVs <7% at a sirolimus concentration of 13.1 microg/l in routine use; the instrumentation proved to be reliable and required minimal maintenance. Clin Chem
21
SIROLIMUS (RAPAMYCIN)-BASED THERAPY IN HUMAN RENAL TRANSPLANTATION
Carl G. Groth, Lars Bäckman, José-Maria Morales et al. · Transplantation · 1999 · 883 citations
Rapamycin inhibits vascular smooth muscle cell migration.
Michael Poon, Steven O. Marx, Richard L. Gallo et al. · Journal of Clinical Investigation · 1996 · 512 citations · Full text
Therapeutic drug monitoring of sirolimus: correlations with efficacy and toxicity
BD Kahan, KL Napoli, PA Kelly et al. · Clinical Transplantation · 2000 · 243 citations
Uwe Christians, Wolfgang Jacobsen, Natalie J. Serkova et al. · Journal of Chromatography B Biomedical Sciences and Applications · 2000 · 169 citations