IEEE Sensors Journal · 2012 · 87 citations · 22 references
EngineeringMechatronics EngineeringInstrumentationMovement AnalysisSensorsAngular MeasurementCalibrationMechanical MeasurementOptical InstrumentationOptical SensorsVibration MeasurementAccelerometer CalibrationAccelerometer SensorsFiber Bragg Grating SensorsFiber Bragg GratingsInclinometersInclinometryOptical Fiber SensorsResonance Frequencies
In this paper, we describe the implementation and test of an optical fiber biaxial accelerometer and inclinometer based on fiber Bragg gratings. The proposed sensor is a low cost and simple solution to measure acceleration and relative rotation in two orthogonal directions, which can be used for structural health monitoring. Sensitivities of 87.848 and 92.351 pm.g <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> , for each sensitive direction with resonant frequencies of 846.01 and 845.33 Hz, respectively, are achieved. For the inclinometer, the tilt sensitivities are 1.43 ± 0.03 and 1.38 ± 0.03 pm/o for each orthogonal sensitive direction for angular rotations smaller than 45°. For inclinations higher than 45°, a suitable calibration expression is presented.
22
In-fibre Bragg grating sensors
Yun-Jiang Rao · Measurement Science and Technology · 1997 · 1.6K citations
Optical Fiber Accelerometer System for Structural Dynamic Monitoring
Paulo Antunes, Hugo Lima, Nélia Alberto et al. · IEEE Sensors Journal · 2009 · 150 citations