Applied Spectroscopy · 1989 · 36 citations · 29 references
Natural SciencesChemistryMaterials ScienceAnalytical ChemistrySpectroscopic AnalysisSpectroscopyAtomic SpectroscopyInorganic SpectroscopyRaman SpectroscopyFunctional Group IdentificationRaman Data AnalysisRaman Spectral Interpretation
Micro-Raman spectroscopy has been utilized to examine the spectra of solid samples of α-UF 5 , β-UF 5 , UF 6 , three types of UO 2 F 2 , the powder residue from a static UF 6 release, and γ-UO 3 . The spectra are presented and compared to previous literature values, with new features indicated where appropriate. With the implied constraint of proper sample handling, micro-Raman spectroscopy is a useful technique for the ready identification of uranium fluorides, oxyfluorides, and oxides.
29