Analytical Chemistry · 1996 · 357 citations · 17 references
Natural SciencesChemical EngineeringChemistryAnalytical ChemistryBiosensorsElectrochemistryAquatic ChemistryElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsEnvironmental BiosensorsWorking ElectrodesAmperometric BiosensorsAmperometric DetectionAmperometric SensingAmperometric SensorsDissolved OxygenElectrochemical Environmental SensingElemental Sulfur OxidationPlatinum Electrodes
The microsensor builds on the Clark‑type oxygen microsensor principle. The authors developed a new amperometric microsensor to detect dissolved H₂S in aquatic environments. The sensor uses a glass‑coated platinum working electrode and guard electrode, polarized at +85 to +150 mV, sealed with a silicone membrane and filled with ferricyanide; H₂S diffuses through the membrane, is oxidized to ferrocyanide, which is reoxidized at the electrode to produce a current proportional to H₂S concentration, and the device was calibrated in a flow‑through cell with a coulometric sulfide generator. The sensor enables high spatial and temporal resolution measurements of dissolved H₂S, making difficult studies feasible.
A new amperometric microsensor for detection of dissolved H2S in aquatic environments was developed. The design of the microsensor is based on the same principle as the Clark-type oxygen microsensor. The sensor is equipped with a glass-coated platinum working electrode and a platinum guard electrode positioned in an outer glass casing (tip diameter 20−100 μm). Both working electrode and guard electrode were polarized at a fixed value in the range from +85 to + 150 mV with respect to a counter electrode. The outer casing is sealed with a thin silicone membrane and filled with a buffered electrolyte solution containing ferricyanide (K3[Fe(CN)6]) as redox mediator. Hydrogen sulfide penetrates the silicone membrane and is oxidized by K3[Fe(CN)6], resulting in the formation of elemental sulfur and ferrocyanide (K4[Fe(CN)6]). The latter is electrochemically reoxidized at the exposed end of the platinum working electrode, thereby creating a current that is directly proportional to the dissolved H2S concentration at the sensor tip. The sensor was characterized and calibrated in a flow-through cell combined with a coulometric sulfide generator. Difficult studies including the determination of H2S with high spatial and temporal resolution seem to be possible.
17
E.I. Hamilton · Marine Pollution Bulletin · 1984 · 3.7K citations
Surendra K. Saxena, Y. Fei · Geochimica et Cosmochimica Acta · 1988 · 1.8K citations
An oxygen microsensor with a guard cathode
Niels Peter Revsbech · Limnology and Oceanography · 1989 · 1.1K citations · Full text
Paul J. Brendel, George W. Luther · Environmental Science & Technology · 1995 · 414 citations
Natural Sciences, Earth Sciences, Environmental Sciences +15