Applied Optics · 1971 · 21 citations · 8 references
Natural SciencesPhysicsOpticsRadiation DosimetryRadiation MeasurementAbsorbed DoseDosimetry InstrumentationHolographyInterferometryRadiation Dose MeasurementThree-dimensional Dose DistributionDose Distribution MappingEnergy Deposition ProfilesHolographic InterferometryInterferometer DesignLaser Irradiation DosimetryTemperature Rise AnalysisThree-dimensional Dose CalculationThree-dimensional Dose Reconstruction
An apparatus has been designed for real-time and double-exposure holographic interferometry to determine radiation absorbed dose distributions in transparent liquids. The change in refractive index of the liquid due to a temperature rise after irradiation is measured interferometrically. In a cylindrically symmetrical radiation field, the dose distribution can be computed from data supplied by the reconstruction of the holographic interferogram taken as side-view profile of the change in optical pathlength. Relatively inexpensive components such as a low-powered He-Ne laser together with a conventional photographic shutter and low-cost mirrors and lenses were used. The mathematical procedure for unfolding the three-dimensional dose distribtion is described, and an example is given for use with a high-intensity, pulsed, 2-MV electron source.
8
L. O. Heflinger, R. F. Wuerker, Robert Brooks · Journal of Applied Physics · 1966 · 251 citations
Natural Sciences, Physics, Metrology +12