Lab on a Chip · 2011 · 55 citations · 18 references
EngineeringBioengineeringBiomedical EngineeringMicroelectromechanical SystemsSensorsSpectroscopyBiomedical MemsMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMagnetic Resonance SpectroscopyMedical ImagingMedical Imaging InstrumentationHigh-resolution ImagingHigh-resolution Magnetic Resonance ImagingHigh-resolution Nuclear Magnetic Resonance SpectroscopyMagnetic ResonanceMagnetic Resonance Imaging AcquisitionMagnetic Resonance Imaging InstrumentationMagnetic Resonance PhysicsModular Platform Architecture
The authors present a lab‑on‑a‑chip modular platform for magnetic‑resonance investigation of sub‑millimetre samples. The platform uses a phased array of microcoils combined with macroscopic surface coils, fabricated via automatic wire bonding and MEMS, to provide an 18.3 mm² flat MR‑sensitive area with B0 uniformity better than 0.25 ppm. The system achieves high‑resolution MRI and NMR spectroscopy, imaging fish oocytes at 30 × 30 μm² with CNR 10 in 13 min 39 s, and resolving a water phantom to 11 ppb linewidth with SNR 28 in 12 s.
We present a lab on a chip (LOC) compatible modular platform for magnetic resonance (MR)-based investigation of sub-millimetre samples. The platform combines the advantages offered respectively by microcoils (high resolution at the microscale) and macroscopic surface coils (large field of view) as MR-detectors and consists of a phased array of microcoils (PAMs) providing a flat MR-sensitive area of 18.3 mm2 with a B0-field uniformity better than 0.25 ppm in the sensor centre area. We demonstrate both high-resolution magnetic resonance imaging (MRI) and NMR spectroscopy using this platform. To demonstrate the application for biological samples, we report MR imaging of fish oocytes with an in-plane resolution of 30 × 30 μm2 and a contrast to noise ratio of 10 for a scan time of only 13 min 39 s. We have also demonstrated high-resolution spectroscopy of a water phantom achieving 11 ppb (4.5 Hz at 400 MHz) linewidth and an SNR of 28 for only 12 s scan time. State of the art automatic wire bonding technology in conjunction with MEMS techniques has been employed to manufacture the platform with potential applications in MR-investigation of planar samples.
18
P. B. Roemer, W. A. Edelstein, Cecil E. Hayes et al. · Magnetic Resonance in Medicine · 1990 · 2.3K citations
Nuclear magnetic resonance imaging of a single cell
James B. Aguayo, Stephen J. Blackband, Joseph S. Schoeniger et al. · Nature · 1986 · 330 citations
Planar microcoil-based microfluidic NMR probes
C. Massin, Franck Vincent, Alexandra Homsy et al. · Journal of Magnetic Resonance · 2003 · 211 citations · Full text