Spectroscopic diagnostics in a highly constricted oxygen arc

John Peters, J. Heberlein, Jon Lindsay

Journal of Physics D Applied Physics · 2007 · 43 citations · 14 references

Concepts

Abstract

Plasma properties in a highly constricted arc were measured using spectroscopic techniques. The arc configuration studied is typical of those produced by plasma cutting equipment. Temperatures and electron densities in the arc were measured using several different emission lines and several different methods for property calculation. Factors such as fluctuations in the arc intensity, arc asymmetry and the validity of the assumptions used for property calculation were shown to affect the accuracy of the measurements. Selection of the temperature measurement method can influence the measurement results. For this arc configuration, methods which use oxygen ion emission lines provide the most accurate results. The measurement methods developed in this study were used to investigate differences in arc properties related to arc current and nozzle diameter. Large changes in the temperature and electron density due to shocks were measured in the under-expanded region near the nozzle exit.

References

14