Review of Scientific Instruments · 2013 · 24 citations · 16 references
EngineeringNuclear EngineeringPhysicsFusion EngineeringPlasma PhysicsUncertainty QuantificationDiagnostic UncertaintyMagnetic Confinement FusionMeasurement ErrorMeasurement UncertaintyUncertainty AnalysisUncertainty EstimationEquilibriumMagnetic DiagnosticsMagnetic Equilibrium ReconstructionMagnetic Field MeasurementsPlasma Equilibrium ReconstructionSystematic UncertaintiesTokamak EquilibriumTokamak Physics
The analysis of uncertainties of magnetic measurements in equilibrium reconstruction is carried out on the EAST (Experimental Advanced Superconducting Tokamak) tokamak. It is shown that uncertainties of magnetic diagnostics are about 0.2% and 10 mWb for flux loops and 0.6% and 20 G for magnetic probes. Analyzing the sensitivity of the magnetic data uncertainty in the plasma shape reconstruction is presented, based on EFIT fixed boundary and fitting mode and applying overall uncertainty as fitting weight in EFIT. It is found that reconstruction uncertainties are ranged in 0.5-1.4 cm for 6 control segments, less than 0.8 cm for X-points, and 1.0-1.6 cm for strike points with 95% confidence, in the last experimental campaign on the EAST tokamak.
16
Reconstruction of current profile parameters and plasma shapes in tokamaks
L. L. Lao, H. St. John, R.D. Stambaugh et al. · Nuclear Fusion · 1985 · 1.8K citations
Magnetic diagnostic system of the DIII-D tokamak
E. J. Strait · Review of Scientific Instruments · 2006 · 190 citations
Magnetic analysis of non-circular cross-section tokamaks
J.L. Luxon, Ben Brown · Nuclear Fusion · 1982 · 145 citations