IEEE Transactions on Reliability · 1981 · 149 citations · 5 references
EngineeringElectrical EngineeringAgingPerformance MeasurementThermal AnalysisDurabilityDurability TestingMaterial DegradationMaterial Degradation AssessmentMaterial DeteriorationReliabilityBreakdown StrengthDegradationElectrical Breakdown StrengthElectrical InsulationInsulation AgingInsulation Performance DegradationPerformance DegradationPerformance Degradation Modeling
The performance of many products degrades as the product ages. Such degradation is usually slow but can be accelerated by a high `stress'. For example, the breakdown strength of electrical insulation depends on age and temperature. In some tests, the performance of a test unit is measured only once at a chosen age. For example, an insulation specimen yields only one breakdown measurement. A model and analyses for such data are described in this tutorial article. Also described is a method for estimating the distribution of time to failure, defined to be the age when performance degrades below a specified level.
5