Physics in Medicine and Biology · 2007 · 34 citations · 30 references
EngineeringNuclear EngineeringPhysicsNuclear PhysicsRadiation PhysicsRadiation ShieldingAccelerator ShieldingNeutron ShieldingProton TherapyRadiation TherapyShielding DesignShielding For Particle AcceleratorsCollimator DesignCollimator ShieldingIntensity-modulated Proton TherapyParticle-in-cell SimulationsPhoton ShieldingRadiation Shielding AnalysisShieldingShielding Analysis
In this paper, we present the shielding analysis to determine the necessary neutron and photon shielding for a laser-accelerated proton therapy system. Laser-accelerated protons coming out of a solid high-density target have broad energy and angular spectra leading to dose distributions that cannot be directly used for therapeutic applications. A special particle selection and collimation device is needed to generate desired proton beams for energy- and intensity-modulated proton therapy. A great number of unwanted protons and even more electrons as a side-product of laser acceleration have to be stopped by collimation devices and shielding walls, posing a challenge in radiation shielding. Parameters of primary particles resulting from the laser-target interaction have been investigated by particle-in-cell simulations, which predicted energy spectra with 300 MeV maximum energy for protons and 270 MeV for electrons at a laser intensity of 2 x 10(21) W cm(-2). Monte Carlo simulations using FLUKA have been performed to design the collimators and shielding walls inside the treatment gantry, which consist of stainless steel, tungsten, polyethylene and lead. A composite primary collimator was designed to effectively reduce high-energy neutron production since their highly penetrating nature makes shielding very difficult. The necessary shielding for the treatment gantry was carefully studied to meet the criteria of head leakage <0.1% of therapeutic absorbed dose. A layer of polyethylene enclosing the whole particle selection and collimation device was used to shield neutrons and an outer layer of lead was used to reduce photon dose from neutron capture and electron bremsstrahlung. It is shown that the two-layer shielding design with 10-12 cm thick polyethylene and 4 cm thick lead can effectively absorb the unwanted particles to meet the shielding requirements.
30
T. Tajima, J. M. Dawson · Physical Review Letters · 1979 · 4.6K citations
Intense High-Energy Proton Beams from Petawatt-Laser Irradiation of Solids
R. A. Snavely, M. H. Key, S. P. Hatchett et al. · Physical Review Letters · 2000 · 1.7K citations
Radiological Use of Fast Protons
Robert R. Wilson · Radiology · 1946 · 1.4K citations
Natural Sciences, Physics, Radiology +14
Forward Ion Acceleration in Thin Films Driven by a High-Intensity Laser
A. Maksimchuk, S. Gu, Kirk Flippo et al. · Physical Review Letters · 2000 · 726 citations
Laser acceleration of quasi-monoenergetic MeV ion beams
B. M. Hegelich, B. J. Albright, J. A. Cobble et al. · Nature · 2006 · 696 citations