Physics in Medicine and Biology · 2007 · 104 citations · 13 references
MedicineNuclear EngineeringNuclear MedicineMedical PhysicsRadiation DosimetryRadiation TransportMedical Imaging PhysicsMonte Carlo DosimetryNuclear Medicine PhysicsPatient-specific DosimetryPhantom DosimetryRadiation TherapyAbsorbed Dose EffectsDepth Dose DistributionDose Depth CurveGafchromic Film DosimetryLateral Dose ProfilesMagnetic Field EffectsMonte Carlo Dose SimulationRadiation Dose Effects
The MRI-linear accelerator system, currently being developed, is designed such that the patient is irradiated in the presence of a magnetic field. This influences the dose distribution due to the Lorentz force working on the secondary electrons. Simulations have shown that the following dose effects occur: the build-up distance is reduced, the lateral profile becomes asymmetric in the direction orthogonal to the magnetic field and at tissue-air interfaces the dose increases due to returning electrons. In this work, GafChromic film measurements were performed in the presence of a magnetic field to experimentally quantify these dose effects. Depth-dose curves were measured in a PMMA-air-PMMA phantom and the lateral profiles were measured in a homogeneous PMMA phantom with the photon beam protruding over the edges of the phantom. The measurement results confirmed the magnetic field dose effects that were predicted by simulations. This enabled us to verify Geant4 Monte Carlo simulations of these MRI-linac specific dose effects: the relative agreement for the depth-dose curves between measurements and simulations was within 2.2%/1.8 mm. The relative agreement for the lateral profiles was 2.3%/1.7 mm. Overall, the magnetic field dose effects that are expected for irradiation with the MRI-linac can be modelled using Geant4 Monte Carlo simulations within measurement accuracy.
13
An Introduction to Numerical Analysis
F. S., Kendall Atkinson · Mathematics of Computation · 1990 · 3.1K citations
A technique for the quantitative evaluation of dose distributions
Daniel A. Low, William B. Harms, Sasa Mutic et al. · Medical Physics · 1998 · 2.9K citations · Full text
Precise radiochromic film dosimetry using a flat-bed document scanner
Slobodan Dević, Jan Seuntjens, E Sham et al. · Medical Physics · 2005 · 569 citations
Introduction to Numerical Analysis
W. G., F. B. Hildebrand · Mathematics of Computation · 1976 · 500 citations
Alexander Raaijmakers, B.W. Raaymakers, J J W Lagendijk · Physics in Medicine and Biology · 2005 · 350 citations