Optics Express · 2008 · 111 citations · 14 references
EngineeringBiomedical EngineeringMaterials ScienceOpticsPhotonicsSensorsNanosensorsOptical BiosensingOptical SensingOptical SensorsOptical SpectroscopyRefractive IndexLabel-free DetectionLabel-free Single-molecule DetectionLaser LinewidthPhotonic Crystal LasersPhotonic Crystal SensorsRefractive Index SensingSensitivitySpectrometer Resolution
We demonstrate refractive index sensing using photonic crystal point shift nanolasers. These lasers operate continuously at room temperature by photopumping in a liquid, and exhibit a 50-dB peak intensity over the background level and a spectral linewidth of < 26 pm, the resolution limit of the present experiment. The lasing wavelength shifts by soaking in different liquids; the wavelength to index sensitivity was 350 nm/RIU, the highest value recorded to date for nanocavity- based sensors. An index resolution of 9.0 x 10(-5) was thus confirmed, leading to an expectation of a resolution of < 10(-6). We propose and demonstrate a spectrometer-free sensor based on nanolasers in an array configuration. These will be disposable sensors with very simple optical I/O. They are anticipated to be integrated with biochips and used for label-free single molecule detection.
14
Integrated optofluidics: A new river of light
Christelle Monat, P. Domachuk, Benjamin J. Eggleton · Nature Photonics · 2007 · 951 citations · Full text
Protein detection by optical shift of a resonant microcavity
Frank Vollmer, Dieter Braun, Albert Libchaber et al. · Applied Physics Letters · 2002 · 902 citations