IEEE Transactions on Biomedical Engineering · 1981 · 65 citations · 12 references
PharmacyPhysiologyCompartmental AnalysisCompartmental ModelingPhysiological Systems ModelingModel FittingMulti-compartment ModelsPhysiologically Based Compartmental ModelingPulmonary MechanicsRespiratory BiomechanicsRespiratory System ModelingCompartmental Parameter EstimationLung Mechanics ModelingRandom NoiseRespiratory Impedance MeasurementRespiratory Muscle ModelingRespiratory System Mechanics
Four iterative parameter estimation algorithms were used to obtain estimates in three parallel compartment models of the respiratory system. The stability of the parameter estimates and the agreement between the forced random noise impedance data and the model's response were evaluated for each algorithm-model combination. The combination of a two-stage simplex algorithm with a five element model provided the most stable parameter estimates and the second best fit to the data.
12
A Simplex Method for Function Minimization
J. A. Nelder, R. Mead · The Computer Journal · 1965 · 28.9K citations