Wide-angle ITER-prototype tangential infrared and visible viewing system for DIII-D

C.J. Lasnier, S. L. Allen, R. Ellis, M.E. Fenstermacher, A.G. McLean, William H. Meyer, Kevin L. Morris, Lynn G. Seppala, Kyle N. Crabtree, M. A. Van Zeeland

Review of Scientific Instruments · 2014 · 35 citations · 1 references

DOIFull text

Open access

Concepts

Abstract

An imaging system with a wide-angle tangential view of the full poloidal cross-section of the tokamak in simultaneous infrared and visible light has been installed on DIII-D. The optical train includes three polished stainless steel mirrors in vacuum, which view the tokamak through an aperture in the first mirror, similar to the design concept proposed for ITER. A dichroic beam splitter outside the vacuum separates visible and infrared (IR) light. Spatial calibration is accomplished by warping a CAD-rendered image to align with landmarks in a data image. The IR camera provides scrape-off layer heat flux profile deposition features in diverted and inner-wall-limited plasmas, such as heat flux reduction in pumped radiative divertor shots. Demonstration of the system to date includes observation of fast-ion losses to the outer wall during neutral beam injection, and shows reduced peak wall heat loading with disruption mitigation by injection of a massive gas puff.

References

1