Basic concepts of temperature determination from self-reversed spectral lines

H. Schneidenbach, Steffen Franke

Journal of Physics D Applied Physics · 2008 · 18 citations · 19 references

Concepts

Abstract

Complex high-pressure plasmas have become increasingly important in technical applications such as high-intensity discharge lamps. The knowledge of temperature distributions is of basic interest for the understanding of the physical mechanisms in these plasmas and for a selective manipulation of their properties. It is shown that self-reversed spectral lines provide a powerful diagnostic tool for temperature determination. The two most important approaches for the corresponding data analysis are reviewed and their limitations are discussed. On the basis of these approaches a new method is proposed which avoids the main limitations especially in the application to resonance lines. The temperature has been determined in a Hg/Ar and a Hg/Ar/TlI high-pressure discharge. Measured spectral radiances of the Hg 546.1 and 253.7 nm as well as Tl 377.6 nm lines are analysed and the potentials of the different methods are demonstrated.

References

19