Classical and Quantum Gravity · 1993 · 19 citations · 5 references
EngineeringMechanical EngineeringPhysicsGravityStructural DynamicsVibrationDamped VibrationGravitational WavesVibration IsolationVibration MeasurementDampingGravitational Wave DetectionIsolator SystemsIsolatorsLow-frequency Vibration IsolationNoise FloorNormal ModesNumerical Modelling
Through a combination of experiment and numerical modelling, we show that vibration isolators using cantilever springs can be used to achieve vibration levels below 10-20 m/ square root Hz for frequencies above 100 Hz, and that this performance can probably be achieved for frequencies as low as 25 Hz. Damping or high Q normal modes in all metal isolator structures can be relatively easily achieved by a combination of active and narrow band eddy current damping while the use of a single-stage ultra-low-frequency pre-isolator can eliminate the need for such damping. Utilizing an improved sapphire transducer, new measurements of the isolator's performance are presented. The measurement noise floor reaches 10-15 m/ square root Hz for vertical displacements and 10-14 m/ square root Hz for horizontal displacements.
5
LIGO: The Laser Interferometer Gravitational-Wave Observatory
Alex Abramovici, W. E. Althouse, R. W. P. Drever et al. · Science · 1992 · 2.3K citations
Natural Sciences, Astronomy, Physics +16
Flow visualization in fluid mechanics
P. Freymuth · Review of Scientific Instruments · 1993 · 74 citations
Computing, Physics, Visualization +10