Journal of Lightwave Technology · 1996 · 24 citations · 6 references
MedicineNuclear EngineeringRadiation DosimetryRadiation PhysicsRadiation SafetyAbsorbed DoseBiological Effects Of RadiationHigh-dose Radiation EffectsRadiation Dose MeasurementRadiation Risk AssessmentRadiation SensitivityDose-rate EffectsNatural Radioactivity MeasurementRadiation Dose AssessmentRadiation Dose EffectsRadiation-induced DegradationRadioactivity MeasurementSubsea Power CablesTotal Dose
For undersea cables radiation doses between 2.5 and 25 rad are to be expected during a working life of 25 years. The majority of previous investigations of the radiation sensitivity of optical fibers, however, apply dose rates /spl gsim/1 rad/s and total dose values /spl gsim/3/spl times/10/sup 3/ rad. The present paper describes /sup 60/Co irradiations of a Ge-doped single mode fiber with dose rates between 10/sup -4/ and 20 rad/s. Expected loss increase of an undersea optical fiber cable at 1550 nm wavelength with a temperature of 2/spl deg/C is derived by three different methods. The most comfortable and reliable one, the 'dose rate transformation method', yields, for example, a loss of only 0.0244 dB/100 km after 25 years of irradiation with a dose rate of 0.4 rad/s. This method could be the basis of a standard test procedure for the effect of natural radioactivity on optical fibers for very long repeaterless terrestrial and undersea cables.