Electrochemical behaviour of 254SMO stainless steel in comparison with 316L stainless steel and Hastelloy C276 in HCl media

Lorenzo De Micheli, Celso Antônio Barbosa, Arnaldo Homobono Paes de Andrade, S.M.L. Agostinho

British Corrosion Journal · 2000 · 19 citations · 5 references

Concepts

Abstract

The electrochemical behaviour of 254SMO stainless steel in HCl solutions has been studied and compared with that observed for other alloys using open circuit potential measurements, potentiodynamic polarisation curves, and SEM analysis techniques. 254SMO does not display pitting corrosion at room temperature in HCl solutions having concentrations ≤5·0M. Its performance is comparable with that of Hastelloy C276 in HCl media in solutions of strength ≤1·0M. The critical pitting temperature for 254SMO exceeds 76°C in 3M HCl solutions.

References

5