Knee Surgery Sports Traumatology Arthroscopy · 2006 · 118 citations · 42 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryMovement AnalysisOrthopedic BiomechanicsOrthopedicsJoint Motion AnalysisKnee ArthroplastyKnee BiomechanicsGait KinematicsKnee Joint MechanicsKnee StabilityTotal Knee Arthroplasty Biomechanics
The purpose of this study was to compare knee kinematics in patients with bi-cruciate preserving total knee arthroplasty and posterior cruciate ligament (PCL) preserving total knee arthroplasty. Five knees received PCL-retaining arthroplasty and nine knees received both cruciate-retaining arthroplasty (ACL/PCL knees). We studied treadmill gait, stair stepping, and maximum flexion activities using lateral fluoroscopy and shape matching. For maximum flexion, the ACL/PCL knees showed 6 mm more posterior translation of the lateral condyle (p < 0.05). For the stair activity, posterior translations of the lateral condyle were significantly greater in the ACL/PCL knees from 30 degrees to 70 degrees flexion (p < 0.05). Both condyles in the ACL/PCL knees showed greater posterior translation in the stance and swing phases of gait than in the PCL knees (p < 0.05). Preserving both cruciate ligaments in total knee arthroplasty appears to maintain some basic features of normal knee kinematics in these activities.
42
Rationale of the Knee Society clinical rating system.