Structural Concrete · 2013 · 29 citations · 4 references
EngineeringCivil EngineeringMaterials ScienceMechanical Behavior Of MaterialsStructural EngineeringStructural MaterialsDesign For StrengthJoint DesignJoint StrengthStrengthening MechanismsStress AnalysisStructural ReinforcementDesign CodesJoint DetailingJoint SpacingJoint Spacing EffectsJoint Stress AnalysisJoint Stress DistributionTension NetworksTension Testing
Abstract Staggering lapped joints increases the complexity of detailing and steel fixing, and may require additional resources and slow construction on site. Major design codes encourage staggering lapped joints in tension by imposing a penalty on lap length depending on the proportion of bars lapped at the same section. There are, however, inconsistencies in the value of the coefficients to be applied, and little evidence is available for validation. A programme of 17 physical tests found no evidence of an increase in strength when laps were staggered, and when allowance is made for increases in transverse spacing, staggering was found to reduce lap strength. Differences in the distribution of bond stress through a lap joint and in the share of the tension force taken by continuous and lapped bars are demonstrated to be responsible for the reduction.
4
Bond Strength of Lap-Spliced Bars
Erdem Canbay, Robert Frosch · ACI Structural Journal · 2005 · 90 citations
The splitting forces generated by bond
John Cairns, K. A. Jones · Magazine of Concrete Research · 1995 · 63 citations
Lap Splices of Bars in Bundles
John Cairns · ACI Structural Journal · 2013 · 17 citations