IET Electric Power Applications · 2012 · 92 citations · 15 references
EngineeringElectrical EngineeringDiagnostic AssessmentElectric MachinesPower ElectronicsDiagnosisDiagnosticsElectrical System DiagnosticsFault DetectionFault DiagnosisElectric Motor Fault DiagnosisFault Diagnosis In Motor DrivesIsolationPermanent Magnet Synchronous MachinesPermanent Magnet Synchronous Motor DrivesPermanent Magnet Synchronous MotorsSynchronous Motor DrivesVoltage Measurement
A sectoral diagnosis method for open switch faults of inverter-fed permanent magnet synchronous motor (PMSM) drives have been described. The proposed diagnosis method defines separate residuals for each of the six switches as a sectoral average of the difference between a reference and measured pole voltage instead of direct use of the instantaneous difference, which has varying AC quantity within one cycle of rotation. How to determine plausible thresholds is described and the effectiveness and limitation of the proposed method are analysed. Several sets of experimental results validate the detection and isolation capability of the proposed method.
15