Muscle & Nerve · 2006 · 121 citations · 24 references
MedicineRehabilitation MedicineExercise TestingPhysical TherapyPulmonary Function TestingFunctional Capacity AssessmentFunctional Capacity EvaluationMuscle Strength TestingMuscular DystrophyMuscular StrengthNeuromuscular Function AssessmentInterrater ReliabilityMulticenter Clinical TrialsMulticenter TrialsMuscular Dystrophy EvaluationOutcome MeasuresOutcome Measures ValidationPrimary Outcome AnalysisTimed Forced Vital Capacity
We studied the reliability of a series of endpoints in an evaluation of subjects with Duchenne muscular dystrophy (DMD). The endpoints included quantitative muscle tests (QMTs), timed function tests, forced vital capacity (FVC), and manual muscle tests (MMT). Thirty-one ambulatory subjects with DMD (mean age 8.9 years; range 5-16 years) were evaluated at eight sites by 15 newly trained evaluators as a test of interrater reliability of outcome measures. Both total QMT score [intraclass correlation coefficient (ICC) 0.96] and individual QMT assessments (ICC 0.85-0.96) were highly reliable. Forced vital capacity and all timed function tests were also highly reliable (ICC 0.97-0.99). MMT was the least reliable assessment method (ICC 0.61). These data suggest that primary surrogate outcome measures in large multicenter clinical trials in DMD should use QMT, FVC, or time function tests to obtain maximum power and greatest sensitivity.
24
The Medical Journal of Australia · 1965 · 591 citations
Clinical trial in duchenne dystrophy. I. The design of the protocol
Michael H. Brooke, Robert C. Griggs, Jerry R. Mendell et al. · Muscle & Nerve · 1981 · 563 citations