New LatticeEngineeringAccelerator PhysicSynchrotron Radiation SourceElectromagnetic CompatibilityElectron EnergyComputational ElectromagneticsLow-emittance LatticeAccelerator TechnologyElectrical EngineeringPhysicsPresent TunnelSynchrotron RadiationMicroelectronicsNatural SciencesParticle PhysicsApplied PhysicsParticle AcceleratorBeam Transport System
In the framework of its upgrade, the ESRF is designing a new lattice to replace the present double-bend achromat structure. This new lattice fulfills the following constraints and requirements: It fits in the present tunnel and keeps the insertion device source points at the same location;Its target horizontal emittance is around 150 pm;It keeps the electron energy at 6 GeV in order to preserve the spectral properties of the present beamlines;It minimizes the radiation losses and the magnet electrical consumption in order to decrease operating costs;The present injector complex is re-used with minor changes.