Journal of Applied Physics · 1952 · 21 citations · 10 references
Natural SciencesMaterials SciencePhysicsCrystal StructureOpticsRadiation DetectionCrystallographyDiffractionX-ray CrystallographyX-ray DiffractionX-ray OpticsDiffractive X-ray OpticsFocusQuartzX-ray Focusing OpticsX-ray Focusing SystemsX-ray Monochromators
A point focusing x-ray monochromator was designed and constructed for low angle scattering studies. The anastigmatic point focus is achieved by means of two cylindrically bent quartz crystals whose focal circles are mutually perpendicular. The beam, emanating from the copper target of an x-ray tube, is reflected in succession, first from the crystal defining the horizontal focal circle, and second from the crystal defining the vertical focal circle following which it comes to a monochromatic point focus of wavelength 1.537A (CuKα1). The sample to be studied is placed between the second crystal and the point focus, and the scattered beam is detected by means of a photographic film placed at the point focus, at right angles to the undeviated beam, the latter being suppressed by means of an absorber, or allowed to pass through a hole in the film. Mathematical analysis, in which a ray was traced through the two-crystal system, revealed correctly the shape and size of the point focus, and the possibility of reducing the latter in size by stopping down the beam emerging from the target.
10
Particle Size Determination by Soft X-Ray Scattering
K. L. Yudowitch · Journal of Applied Physics · 1949 · 46 citations · Full text
Latex Particle Size from X-Ray Diffraction Peaks
K. L. Yudowitch · Journal of Applied Physics · 1951 · 34 citations