IBM Journal of Research and Development · 1974 · 147 citations · 2 references
Natural SciencesChemistryMaterials ScienceAnalytical ChemistryMaterials CharacterizationThin FilmsElectron Beam PhysicsElectron MicroscopyX-ray DetectionX-ray Fluorescence AnalysisX-ray SpectroscopyCharacteristic X-ray EmissionContinuous Slowing Down ApproximationElectron Probe MicroanalysisElectron ScatteringNondestructive AnalysisRutherford ScatteringX-ray Fluorescence SpectroscopyX-ray Spectroscopy Simulation
Monte Carlo simulation procedure is developed for kilovolt electron beam scattering and energy loss in targets consisting of thin films on thick substrates. Such calculations have direct application to the nondestructive quantitative chemical analysis of ultra-thin films in the electron microprobe (an electron probe x-ray microanalyzer), utilizing characteristic x-ray fluorescence. Angular elastic scattering is calculated in the electron trajectory simulation with the screened Rutherford expression for cross section, and energy loss between elastic scattering events is calculated with the continuous-slowing-down approximation of Bethe. The contribution to x-ray fluorescence from the film due to backscattered electrons from the substrate is accounted for. For elemental films, the Monte Carlo simulation predicts intensity ratios k <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">i</inf> , for characteristic x-rays from the film, referenced to standards of thick elemental samples. No film standards are required, and the mass thickness of any elemental film on any substrate can be determined from theoretical calibration curves. The model has been verified by measurements on films of Si, Cu, and Au on Al <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf> over wide ranges in E <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</inf> , and t. For alloy films, calibration curves are generated and graphically iterated to provide independent analysis of weight fractions C <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">i</inf> and total mass thickness ρt. Films of Mn <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</inf> Bi <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</inf> and Co <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</inf> Pt <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</inf> were successfully analyzed with ρt ≤ 100 µg/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> .
2
Samuel Natelson · Microchemical Journal · 1967 · 377 citations
<i>X-Ray Absorption and Emission in Analytical Chemistry</i>
H. A. Liebhafsky, H. G. Pfeiffer, Earl H. Winslow et al. · Physics Today · 1961 · 137 citations