Correlation between cathode properties, burning voltage, and plasma parameters of vacuum arcs

André Anders, B. Yotsombat, Róbert Binder

Journal of Applied Physics · 2001 · 98 citations · 16 references

Concepts

TL;DR

The study measured arc burning voltages for 54 cathode materials and used energy‑balance analysis to link cohesive energy to discharge properties. The results revealed that arc burning voltage correlates with plasma temperature and, more importantly, with cathode cohesive energy, establishing a cohesive‑energy rule that governs discharge behavior and related secondary relationships.

Abstract

Burning voltages of vacuum arcs were measured for 54 cathode materials and compared with literature data. As anticipated, a correlation between the arc burning voltage and the plasma temperature was found. However, more importantly, a correlation between the cohesive energy of the cathode material and the arc burning voltage could be demonstrated. This link between a cathode material property, the cohesive energy, and a discharge property, the arc burning voltage, is essential for the operation of the vacuum arc discharge because is determines the plasma temperature. Energy balance considerations show that this “cohesive energy rule” is responsible for several other secondary relationships, such as the correlation between the mean ion charge state and the boiling temperature of the cathode.

References

16