Die Messung der Ultraschall‐Diffusion an einer Elektrode und ihre praktische Anwendung

H. Huck

Berichte der Bunsengesellschaft für physikalische Chemie · 1987 · 27 citations · 11 references

Concepts

Abstract

Abstract Under the action of ultrasound ( I up to 2 W/cm 2 ) quasi‐stationary current voltage curves were obtained, from which the densities of the exchange, the diffusion‐limited currents and the transfer coefficient were calculated. The acceleration of diffusion with ultrasound was attributed to surface cavitation involving pulsating bubbles surrounded by microstreaming. At higher sound intensities a limiting current due to cavitation saturation was observed. In order to explain this saturation effect a Langmuir kinetic for the enrichment and the depletion of cavitation bubbles beyond the threshold intensity was proposed. In the case of acoustic resonance ( h = n λ/2) standing waves are generated in the solution. At the pressure loops the sound action has then a maximum. — Reproducible results were only obtained in the presence of cavitation nuclei, how they are given at rough surfaces or at smooth surfaces after adsorption of colloidal particles. The measurements were performed with Pt, glassy carbon and graphite electrodes in solutions of Fe 3+ /Fe 2+ and [Fe(CN) 6 ] 3‐ /[Fe(CN) 6 ] 4‐ . According to the obtained i 0 values it is suspected that the complex bounded cyanid ions are favoring the exchange of electrons between the central atom and the electrode surface by an inner‐sphere mechanism.

References

11