Review of Scientific Instruments · 2011 · 40 citations · 26 references
Natural SciencesPhysicsPlasma PhysicsRadiation MeasurementSpectroscopyCalibrationHigh-temperature PlasmasSpace-based Ultraviolet ObservationsSpectral CalibrationUltraviolet InstrumentationUltraviolet SpectroscopyAbsolute CalibrationAccuracyBremsstrahlungBremsstrahlung RadiationEmissivityExtreme Ultraviolet SpectroscopyRadial Profiles
A precise absolute intensity calibration of a flat-field space-resolved extreme ultraviolet (EUV) spectrometer working in wavelength range of 60-400 Å is carried out using a new calibration technique based on radial profile measurement of the bremsstrahlung continuum in Large Helical Device. A peaked vertical profile of the EUV bremsstrahlung continuum has been successfully observed in high-density plasmas (n(e) ≥ 10(14) cm(-3)) with hydrogen ice pellet injection. The absolute calibration can be done by comparing the EUV bremsstrahlung profile with the visible bremsstrahlung profile of which the absolute value has been already calibrated using a standard lamp. The line-integrated profile of measured visible bremsstrahlung continuum is firstly converted into the local emissivity profile by considering a magnetic surface distortion due to the plasma pressure, and the local emissivity profile of EUV bremsstrahlung is secondly calculated by taking into account the electron temperature profile and free-free gaunt factor. The line-integrated profile of the EUV bremsstrahlung continuum is finally calculated from the local emissivity profile in order to compare with measured EUV bremsstrahlung profile. The absolute intensity calibration can be done by comparing measured and calculated EUV bremsstrahlung profiles. The calibration factor is thus obtained as a function of wavelength with excellent accuracy. It is also found in the profile analysis that the grating reflectivity of EUV emissions is constant along the direction perpendicular to the wavelength dispersion. Uncertainties on the calibration factor determined with the present method are discussed including charge-coupled device operation modes.
26
<i>Techniques of Vacuum Ultraviolet Spectroscopy</i>
James A. R. Samson, Stanley S. Ballard · Physics Today · 1968 · 693 citations
The Large Helical Device (LHD) helical divertor
N. Ohyabu, T. Watanabe, Hantao Ji et al. · Nuclear Fusion · 1994 · 194 citations
Design and performance of the Thomson scattering diagnostic on LHD
K. Narihara, I. Yamada, H. Hayashi et al. · Review of Scientific Instruments · 2001 · 178 citations · Full text