Correlation of B-Mode Ultrasound Imaging and Arteriography With Pathologic Findings at Carotid Endarterectomy

Thomas F.X. O’Donnell

Archives of Surgery · 1985 · 279 citations · 20 references

Concepts

TL;DR

Current noninvasive assessment of extracranial carotid disease relies mainly on hemodynamic changes, yet ulceration and plaque hemorrhage are increasingly recognized as key pathological contributors. The study aimed to evaluate whether B‑mode ultrasound can provide anatomical information comparable to selective four‑vessel arteriography in a prospective blinded comparison with carotid endarterectomy specimens. Ultrasound and arteriography were used to describe ulceration, plaque characteristics—especially hemorrhage—and luminal diameter for each patient undergoing 89 carotid endarterectomies. B‑mode ultrasound detected ulceration with 89 % sensitivity versus 59 % for arteriography, had comparable specificity, and accurately identified plaque hemorrhage with 93 % sensitivity and 84 % specificity, demonstrating its superior noninvasive diagnostic value.

Abstract

Presently most noninvasive methods for assessing extracranial carotid disease have relied on hemodynamic change associated with significant stenosis. Recent evidence has suggested that both ulceration and/or plaque hemorrhage may frequently play an important role in the pathophysiology of carotid disease. To assess the ability of B-mode ultrasound to provide this anatomic information, in a prospective blinded manner we compared B-mode ultrasound and selective four-vessel arteriography to pathologic specimens obtained at the time of 89 carotid endarterectomies. The presence of ulceration, plaque characteristics (particularly hemorrhage), and luminal diameter were described for each modality. While arteriography detected only 16 of 27 ulcerations (sensitivity, 59%), B-mode ultrasound had a greater sensitivity (24/27, 89%). Both modalities had comparable specificities (arteriography, 73%; B-mode ultrasound, 87%). Moreover, B-mode ultrasound was highly sensitive for demonstrating plaque hemorrhage (27/29, 93%), as well as being quite specific (84%). Assessment of luminal reduction by B-mode ultrasound improved with technologist/interpreter experience and was significantly improved by adding real-time spectral analysis. Because of B-mode ultrasound's sensitivity for imaging ulceration and plaque hemorrhage, it offers significant advantages for the noninvasive detection of extracranial carotid disease.

References

20