Translational Vision Science & Technology · 2014 · 15 citations · 5 references
MedicineOphthalmologySurgeryAssistive TechnologyOphthalmic SurgeryProstheticsOcular ImplantsOcular ProsthesesOcular ProstheticsComfortProsthetic Eye MaintenanceRating Scale AnalysisVisual Prosthetics
PURPOSE: To test a prototype magnet system (magnetic levator prosthesis) for the ability to comfortably and non-invasively provide eye opening with maintenance of the blink in people with paralytic ptosis and determine preliminary efficacy for short-term clinical application. METHODS: The prototype device consisted of a magnet on a spectacle frame and a micro-magnet array mounted externally on the eyelid. Participants with unilateral CN III palsy (n=3) trialed the predicate (ptosis crutch) and magnet device. Video analysis was used to quantify changes in eyelid opening and subjective responses were documented with a rating scale. A 20-minute and then a 1-week trial were offered. RESULTS: The magnetic levator prosthesis device was effective to provide eye opening while allowing, at minimum, a volitional blink without ill effects on the eyelid skin or ocular surface. Comfort scores ranged from 6 to 9 out of 10 over 3 evaluations. All patients chose an extended trial of the magnet device and reported continued 8-9/10 comfort and efficacy after the extended 1-week trial. CONCLUSIONS: Comfortable and effective restoration of eye opening with maintenance of the blink is feasible using external static magnets and warrants further study. TRANSLATIONAL RELEVANCE: This is the first careful documentation of the successful use of an externally mounted static magnet system to treat paralytic ptosis.
5
Robot-aided neurorehabilitation
Hermano Igo Krebs, N. Hogan, Mindy Aisen et al. · IEEE Transactions on Rehabilitation Engineering · 1998 · 1.4K citations
Esophageal Sphincter Device for Gastroesophageal Reflux Disease
Robert A. Ganz, Jeffrey H. Peters, Santiago Horgan et al. · New England Journal of Medicine · 2013 · 321 citations · Full text
Medicine, Clinical Sciences, Surgery +16
Prevalence of ocular motor cranial nerve palsy and associations following stroke
Eye · 2011 · 53 citations · Full text
Medicine, Neurology, Neurosurgery +12
A Novel Implantable Glaucoma Valve Using Ferrofluid
Eleftherios I. Paschalis, James Chodosh, Ralph A. Sperling et al. · PLoS ONE · 2013 · 36 citations · Full text
Magnetic Systems for Tarsorrhaphy
Anne Barmettler, Nadee Nissanka, Mark I. Rosenblatt et al. · Ophthalmic Plastic and Reconstructive Surgery · 2014 · 10 citations
Medicine, Ophthalmology, Surgery +9