PLoS ONE · 2014 · 15 citations · 22 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyHybrid ImagingAbdominal Oncology ImagingBody ImagingComputed TomographyMedical ImagingPositron Emission TomographyThoracic Oncology ImagingHelical ReconstructionLung Tumor ImagingMotion Correction In PetPet Image ReconstructionPet-computed TomographyRespiratory Motion CompensationRespiratory Motion CorrectionTumor Volume Measurement
PURPOSE: Respiratory motion causes substantial artifacts in reconstructed PET images when using helical CT as the attenuation map in PET/CT imaging. In this study, we aimed to reduce the respiratory artifacts in PET/CT images of patients with lung tumors using an abdominal compression device. METHODS: Twelve patients with lung cancer located in the middle or lower lobe of the lung were recruited. The patients were injected with 370 MBq of 18F-FDG. During PET, the patients assumed two bed positions for 1.5 min/bed. After conducting free-breathing imaging, we obtained images of the patients with abdominal compression by applying the same setup used in the free-breathing scan. The differences in the standardized uptake value (SUV)max, SUVmean, tumor volume, and the centroid of the tumors between PET and various CT schemes were measured. RESULTS: The SUVmax and SUVmean derived from PET/CT imaging using an abdominal compression device increased for all the lesions, compared with those obtained using the conventional approach. The percentage increases were 18.1% ±14% and 17% ±16.8% for SUVmax and SUVmean, respectively. PET/CT imaging combined with abdominal compression generally reduced the tumor mismatch between CT and the corresponding attenuation corrected PET images, with an average decrease of 1.9±1.7 mm over all the cases. CONCLUSIONS: PET/CT imaging combined with abdominal compression reduces respiratory artifacts and PET/CT misregistration, and enhances quantitative SUV in tumor. Abdominal compression is easy to set up and is an effective method used in PET/CT imaging for clinical oncology, especially in the thoracic region.
22
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Paul Keall, G Mageras, James M. Balter et al. · Medical Physics · 2006 · 2.3K citations · Full text
Effect of respiratory gating on quantifying PET images of lung cancer.
Sadek A. Nehmeh, Yusuf E. Erdi, Clifton C. Ling et al. · PubMed · 2002 · 410 citations
Four‐dimensional (4D) PET/CT imaging of the thorax
Sadek A. Nehmeh, Yusuf E. Erdi, Tinsu Pan et al. · Medical Physics · 2004 · 348 citations
The CT motion quantitation of lung lesions and its impact on PET-measured SUVs.
Yusuf E. Erdi, Sadek A. Nehmeh, Tinsu Pan et al. · PubMed · 2004 · 283 citations