Catheterization and Cardiovascular Interventions · 2014 · 45 citations · 9 references
MedicineCardiologyPediatricsPediatric CardiologyRadiation DosimetryRadiation SafetyCardiac CatheterizationPatient-specific DosimetryPediatric FluoroscopyPediatric Interventional CardiologyPediatric Interventional RadiologyRadiation Exposure In ChildhoodBody Weight IndexingDose Calculations For ChildrenMedical Imaging Radiation DosePediatric CatheterizationPediatric DosimetryRadiation Dose EstimationRadiation Dose ReductionRadiation Safety In Children
OBJECTIVES: We examine normalized air Kerma area product (PKA ) by body weight (PKA /BW) as a reference value of radiation dose and benchmark PKA /BW in pediatric laboratories using a multicenter registry database. BACKGROUND: Reduction of radiation dose is an important quality improvement task in pediatric cardiac catheterization laboratories. Physicians need to agree on a standard method of reporting radiation dose that would allow comparisons to be made between operators and institutions. METHODS: This was a multicenter observational study of radiation dose in pediatric laboratories. Patient demographic, procedural and radiation data including fluoroscopic time and PKA (µGy m(2) ) were analyzed. PKA /BW was obtained by indexing PKA to body weight. RESULTS: A total of 8,267 pediatric catheterization procedures (age <18 years) were included from 16 institutions. The procedures consisted of diagnostic (n = 2,827), transplant right ventricular (RV) biopsy (n = 1,172), and interventional catheterizations (n = 4268). PKA correlated with body weight better than with age and best correlated with weight-fluoroscopic time product. PKA /BW showed consistent values across pediatric ages. Interventional catheterizations had the highest PKA /BW (50th, 75th, and 90th percentiles: 72, 151, and 281 μGy m(2) /kg), followed by diagnostic (59, 105, and 175 μGy m(2) /kg) and transplant RV biopsy (27, 79, and 114 μGy m(2) /kg). CONCLUSION: PKA /BW appeared to be the most reliable standard to report radiation dose across all procedure types and patient age. We recommend PKA /BW to be used as the standard unit in documenting radiation usage in pediatric laboratories and can be used to evaluate strategies to lower radiation dosage in pediatric patients undergoing cardiac catheterizations. © 2014 Wiley Periodicals, Inc.
9
John W. Hirshfeld, Stephen Balter, Jeffrey Brinker et al. · Circulation · 2005 · 436 citations
Patient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac Catheterization
Klaus Bacher, E. Bogaert, Régine Lapere et al. · Circulation · 2004 · 273 citations
Medicine, Cardiology, Pediatrics +17
Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
Koichi Chida, Tadayuki Ohno, Shuhei Kakizaki et al. · American Journal of Roentgenology · 2010 · 137 citations
Medicine, Pediatrics, Radiology +17
George R. Verghese, Doff B. McElhinney, Keith J. Strauss et al. · Catheterization and Cardiovascular Interventions · 2011 · 77 citations
Medicine, Cardiology, Pediatrics +17