Catheterization and Cardiovascular Interventions · 2011 · 77 citations · 14 references
MedicineCardiologyPediatricsRadiation DosimetryRadiation ProtectionRadiation SafetyCardiac CatheterizationPatient Radiation SafetyPatient-specific DosimetryRadiation Dose MeasurementRadiation Exposure In ChildhoodRadiation Risk AssessmentCardiac DosimetryCardiac Radiation DosimetryCongenital Valvular Heart DiseasePediatric DosimetryRadiation Dose EstimationRadiation Dose MonitoringRadiation MonitoringRadiation Safety In Children
OBJECTIVES: This study aimed to characterize radiation dose during cardiac catheterization in congenital heart disease and to assess changes in dose after the introduction of a radiation monitoring policy. BACKGROUND: Minimizing radiation exposure is an important patient safety initiative and relatively few data are available characterizing radiation dose for the broad spectrum of congenital cardiac catheter-based interventions. METHODS: Radiation dose data were reviewed on all cases since 7/1/05 at a single large center. Procedures were classified according to 20 common case types then subdivided into five age categories. Groups with <20 cases were excluded. Radiation dose was estimated by cumulative air KERMA (mGy) and DAP (dose area product, μGym(2)) which were reported as median and interquartile range (IQR). We also examined differences in radiation dose before and after the implementation of a radiation policy. RESULTS: Between 7/1/05 and 12/10/08, 3,365 cases were identified for inclusion. Radiation dose increased with age and procedural complexity. Patients were characterized into low, medium, and high dose categories relative to each other. "Low" dose cases included isolated pulmonary or aortic valvotomy, pre-Fontan assessment, and ASD closure. "High" dose cases involved multiple procedures in pulmonary arteries or veins. After introduction of a radiation policy, there was a significant decrease in radiation dose across a variety of case types, particularly among infants and young children. CONCLUSIONS: Radiation dose in congenital cardiac catheterization varies by age and procedure type. A radiation monitoring and notification policy may have contributed to reduced radiation dose.
14
Patient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac Catheterization
Klaus Bacher, E. Bogaert, Régine Lapere et al. · Circulation · 2004 · 273 citations
Medicine, Cardiology, Pediatrics +17
γ-H2AX Foci as a Biomarker for Patient X-Ray Exposure in Pediatric Cardiac Catheterization
Laurence Beels, Klaus Bacher, Daniël De Wolf et al. · Circulation · 2009 · 168 citations · Full text
Medicine, Cardiology, Radiology +17
Effective doses to patients from paediatric cardiac catheterization.
J. Rassow, A Schmaltz, F Hentrich et al. · British Journal of Radiology · 2000 · 108 citations
Medicine, Pediatrics, Radiology +17