EngineeringEnvironmental EngineeringEnvironmental SciencesPollution ScienceWater Quality EngineeringWater TreatmentMembrane FiltrationNutrient RemovalOrganic Contaminant RemovalWater PollutionActivated Carbon BiofiltersBiofilteringBiofiltrationFilter DepthFilter MediaFiltersNatural Organic Matter RemovalOrganic Matter Removal
Many factors could account for the good performance of coal‐based GAC biofilters, including the quantity of biomass attached to the media. A phospholipid analytical technique was used to measure the amount of biomass attached to the surfaces of drinking water filter media. The method was reproducible and able to detect significant differences in biomass concentrations in different filters and at various depths within filters. The amount of attached biomass decreased as filter depth increased, suggesting that most removal of natural organic matter occurred at the top of the biofilters. The results show that granular activated carbon media were able to hold more biomass than were anthracite and sand media and that concentrations of biomass in anthracite‐sand filters were lower with chlorine in the backwash water.