Immunobead-PCR: a technique for the detection of circulating tumor cells using immunomagnetic beads and the polymerase chain reaction.

Jennifer E. Hardingham, Dusan Kotasek, Belinda J. Farmer, R N Butler, J X Mi, Robert Sage, Alexander Dobrovic

PubMed · 1993 · 121 citations · 3 references

Concepts

Abstract

The presence of tumor cells in the circulation may predict disease recurrence and metastases. We have developed a sensitive technique for the detection of carcinoma cells in blood, using immunomagnetic beads to enrich for epithelial cells and the polymerase chain reaction to identify a tumor marker. The colon carcinoma cell line SW480, homozygous for a K-ras codon 12 mutation, was used to establish optimal conditions. The SW480 cells were serially diluted in normal blood and incubated with immunomagnetic beads labeled with a monoclonal antibody specific for epithelial cells. Cells bound to the beads were retrieved using a magnetic field and the presence of K-ras codon 12 mutations determined by a polymerase chain reaction based analysis. SW480 cells could be detected in dilutions up to 1 SW480 cell/10(5) leukocytes in whole blood.

References

3