Journal of Clinical Microbiology · 1994 · 116 citations · 19 references
Veterinary MedicineInfectious DiseasesMicrobiologyDiagnostic MicrobiologyMedical MicrobiologyMolecular DiagnosticsInfectious Disease DetectionPathogen DetectionRespiratory InfectionsRespiratory Infectious DiseasesRespiratory Pathogen DiagnosticsRespiratory Tract InfectionsMycoplasma Pneumoniae DiagnosticsPathogen Dna DetectionPcr-based DetectionPolymerase Chain Reaction (Pcr) AmplificationPolymerase Chain Reaction (Pcr) AssaysPolymerase Chain Reaction (Pcr) DiagnosticsRespiratory Pathogen TestingSerial Dilution Testing
The sensitivities of three methods of detection of Mycoplasma pneumoniae by a 16S rDNA PCR were compared by using a serial dilution of M. pneumoniae. These methods consisted of a PCR performed directly on cells after a proteinase K pretreatment (direct PCR), a PCR after purification of nucleic acids (DNA-PCR), and a PCR with rRNA sequences as the target after reverse transcription. The direct PCR and the reverse transcription PCR had a sensitivity of 1.5 CFU (approximately 250 genomes). By purification, a 10-fold loss of target DNA occurred, as shown by a 10-fold decrease in sensitivity (15 CFU) of the DNA-PCR. The presence of an excess of human background DNA did not influence the sensitivity of either PCR. The direct PCR was evaluated on samples from patients with respiratory complaints. Direct PCR amplification was possible in 94.9% of the samples, which were tested by amplification of a 326-bp fragment of the beta-globin gene, which was performed to test for the suitability of amplification. Nucleic acid purification was performed on the beta-globin-negative samples, after which only 2% remained negative. A positive correlation between the direct M. pneumoniae PCR and serology, as tested by the microparticle agglutination assay (MAG assay), was found in 88.1% of the cases. A positive MAG assay result was found for samples from 10 (17%) of the patients; samples from 6 (10.2%) of these patients were also positive by PCR. Samples from three patients were found to be positive by the M. pneumoniae PCR and negative by the MAG assay. Persistence of M. pneumoniae, as detected by PCR was observed in three patients. These results indicate that the direct PCR with 16S rDNA could prove to be useful in the detection of M. pneumoniae in respiratory tract samples, although more studies are needed to evaluate the correlation between clinical symptoms and positive test results.
19
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Randall K. Saiki, David H. Gelfand, Susanne Stoffel et al. · Science · 1988 · 17.2K citations
Detection and identification of mycobacteria by amplification of rRNA
Boris Böddinghaus, T. Rogall, T Flohr et al. · Journal of Clinical Microbiology · 1990 · 519 citations · Full text
Long-Term Epidemiology of Infections with Mycoplasma pneumoniae
H. M. Foy, G E Kenny, Marion K. Cooney et al. · The Journal of Infectious Diseases · 1979 · 280 citations