BJOG An International Journal of Obstetrics & Gynaecology · 2012 · 155 citations · 26 references
MedicineGeneticsObstetricsGenomicsMaternal-fetal MedicinePrenatal DiagnosisComparative Genomic HybridizationFetal AnomaliesFetal Anomaly DetectionPrenatal Genetic DiagnosisArray Comparative Genomic HybridizationArray Genomic HybridizationBacterial Artificial Chromosome Array AnalysisMultiplex Ligation-dependent Probe AmplificationPrenatal Copy Number Variant DiagnosisPrenatal Detection Of Copy Number VariantsPrenatal Genomic Imbalance ScreeningPrenatal Genomics
OBJECTIVE: To evaluate the clinical value of prenatal array comparative genomic hybridisation (CGH) in screening for submicroscopic genomic imbalances. DESIGN: Cross-sectional study. SETTING: Tertiary referral centre. POPULATION: From June 2008 to February 2011, 3171 fetuses underwent prenatal array CGH testing and karyotyping at the National Taiwan University Hospital. Indications for invasive prenatal diagnosis included abnormal karyotype, abnormal ultrasound, advanced maternal age and parental anxiety. METHODS: In all, 2497 fetuses were screened with 1-Mb resolution bacterial artificial chromosome array-based CGH, and 674 fetuses with 60-K oligonucleotide array-based CGH. Multiplex ligation-dependent probe amplification, fluorescence in situ hybridization, or 105-K oligonucleotide array CGH provided further confirmation. MAIN OUTCOME MEASURE: Copy number variations identified by array CGH. RESULTS: Array CGH detected numerical chromosome anomalies in 37 (1.2%) fetuses, microdeletion/duplication in 34 (1.1%) fetuses, large deletion/duplication in 13 (0.4%) fetuses, benign copy number changes in 13 (0.4%) fetuses and variation of unknown clinical significance in five (0.2%) fetuses. Array CGH was effective in identifying submicroscopic genomic imbalance in fetuses with de novo balance translocations (2/17, 1.8%), supernumerary marker chromosomes (3/6, 50%), and abnormal prenatal ultrasound findings (33/194, 17.0%). Array CGH detected microdeletions/duplications in 12 fetuses with normal karyotype. CONCLUSION: Prenatal array CGH is effective in screening for submicroscopic genomic imbalance. Array CGH may add 8.2% to the diagnostic field, compared with conventional karyotyping, for fetuses with abnormal ultrasound results, and is particularly useful in fetuses with karyotypic balanced translocation or marker chromosomes. There is a 0.52% baseline risk of submicroscopic genomic imbalance, even in women with an uneventful prenatal examination.
26
Diagnostic Genome Profiling in Mental Retardation
Bert B.A. de Vries, Rolph Pfundt, M.A.R. Leisink et al. · The American Journal of Human Genetics · 2005 · 604 citations · Full text
C Shaw-Smith · Journal of Medical Genetics · 2004 · 510 citations · Full text