High-rate digester mixing study using radioisotope tracer

John Zoltek, Andrew L. Gram

1975 · 10 citations · 0 references

Concepts

Abstract

pare the relative effectiveness of three different high-rate digestion mixing sys tems. Two of the systems utilized forms of gas recirculation; the third relied on liquid sludge recirculation. The study was per formed at the Joint Water Pollution Con trol Plant of the Sanitation Districts of Los Angeles County. This 350-mgd primary treatment plant is ideally suited for this experiment in that it contains three di gesters, identical in physical dimensions, each mixed by one of the three different mixing systems. All of the digesters re ceived raw sludge from the same source. A radioactive tracer was used to measure the degree of mixing because the hetero geneous and opaque nature of digesting sludge makes the use of dye or salt tracers impractical. A submersible radiation de tector was used for sampling. No public health hazard was associated with the radioactive tracer because an isotope with a short half-life was selected. The digester effluent was discharged to the sea, where extreme dilution further minimized the health hazard.